Warranty: | 2 Years |
---|---|
Phase: | Single |
Output Power: | 6000va |
Certification: | CE |
Brand: | Mifasolar |
Type: | DC/AC Inverters |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Model | 5024/48 | 6048 | 6348 | 8048 | 10048 | 12548 | |
Input | 220VAC/110VAC | ||||||
Input voltage range | 220V:154-264VAC±3V(Normal mode) 185-264VAC±3V(UPS mode) \110V:77-132VAC±3V(Normal mode) 92-132VAC±3V(UPS mode) |
||||||
Input frequency | 50/60Hz±5% | ||||||
Rated output power | 5000VA | 6000VA | 6300VA | 8000VA | 10KVA | 12.5KVA | |
Mains output voltage | The output voltage under mains is the same as the input voltage | ||||||
Mains output frequency | The output frequency under mains is the same as the input frequency | ||||||
Output voltage under inverter | 220VAC±10% (110VAC±10%) | ||||||
Output frequency under inverter | 50HZ or 60HZ±1% | ||||||
Output waveform in inverse mode | Pure sine wave | ||||||
Battery type | External lead-acid battery or water battery or lithium battery | ||||||
Battery voltage | 24VDC / 48VDC | ||||||
Battery charging voltage | 27.4VDC / 54.8VDC | ||||||
Maximum photovoltaic array power | 24V: 3200W 48V: 6400W | ||||||
PV input voltage range (MPPT) |
24V: MPPT 30V-150VDC(Customizable 200VDC) 48V: MPPT 60V-150VDC(Customizable 200VDC) |
||||||
Maximum open circuit voltage of photovoltaic display | 24V: MPPT 150VDC(Customizable 200VDC) 48V: MPPT 150VDC(Customizable 200VDC) |
||||||
Optimal Vmp operating range | 24V: MPPT 30V-105VDC 48V: MPPT 60V-105VDC |
||||||
Maximum solar charging current | 120A | ||||||
Maximum AC charging current | 48A / 24A | 29A | 31A | 38A | 48A | 60A | |
Conversion time | ≤10ms(UPSmode)/≤20ms(INVmode) | ||||||
Peak load ratio | (MAX)3:1 | ||||||
Standby power consumption(W) | Ring bull transformer | ||||||
24V:16W / 48V:32W | |||||||
Protection function | Mains off: There is no fuse switch to protect the input overcurrent | ||||||
Inverter: overload protection, short circuit protection, low voltage protection, battery reverse connection protection (fuse) | |||||||
Status display | Dot matrix screen plus LED display/color segment code screen plus LED display | ||||||
Through the page key can view, AC voltage, AC frequency, PV voltage, PV current, output voltage, output frequency, battery voltage, load current and other parameters. | |||||||
LED displays mains, charging status, inverter status, fault status | |||||||
Sound cue | Buzzer according to the different fault code, alarm sound is different, with long and short sound distinguish | ||||||
Operating temperature | 0ºC~40ºC | ||||||
Storage temperature | -15ºC~45ºC | ||||||
Relative temperature | -10ºC~90ºC Condensation free | ||||||
noise | <45dB | ||||||
Machine size(L*W*H)mm | 545*400*200MM | ||||||
Out of package size(L*W*H)mm | 660*460*270MM | ||||||
Net machine weight Kg/Gross weight | 21.3 | 27 | 30 | 37.8 | 39 | 53 | |
Standard for ex-factory inspection report | Random standard :1 manual, 1 fuse, 2 C45 cord end terminals | ||||||
Random parts |
Guangzhou MiFaSolar Energy Co.,Ltd. is a leading high-tech enterprise that specializes in the research and development,design, production, sales, installation, and service of solar energy products. Our products including solar panels, inverters, energy storage batteries and the whole solar system,are widely used byenterprises both domestically and abroad.
Our fast delivery speed and high-quality after-sales service help us meet the diversified needs of our customers.The products are well-liked and trusted by our clients, and exported to over 100 countries and regions.
Q: How does an inverter work?
A: An inverter is a device which converts alternating current (AC) power supply with direct current(DC).
Q: What size inverter should I get?
A: Inverter capacity is measured in Watts which should be higher than the total watts of all the devices that you plan on running
simultaneously. The size of an inverter system has nothing to do with how many solar panels you have or how much battery capacity you have, it is only relevant to the size of your AC loads.
F: What are the advantages of an inverter system?
A: Unlike generators, inverter systems are very quiet, do not emit fumes and can be kept and run indoors. For people living in sectional title complexes, inverters are often the most effective option.
F: Can I use my inverter for my solar installation?
Q: This will depend on the type of inverter you select as while many are solar-ready, most off-the-shelf inverters are not. If
your inverter is not solar-ready, you will need a solar conversion kit or a solar charge controller to use in conjunction with
your inverter.
F: What type of battery should I be using with my inverter?
Q: The inverters are best used with deep cycle batteries because they tend to maintain a consistent voltage more efficiently, are longer lasting than starter batteries.
Suppliers with verified business licenses